Howto use tips:The DATA I/O works with PROlink 2.7 under MS-DOS. The Cable to use with it is a Null Modem cable but with a Female DB-25 connector (attention the DB-25 plug is female while it is Male for the PC)The software is like the programmer so not easy to use.
On the Series 22 I think default is a very low baudrate 600? I enter this sequence on it to do communication with promlink:
Select DA
Select Select Select Select Select Select Select Select (display reads 'BAUD 9600')
Start (display reads 'BAUD RATE **')
Select F1 (display reads 'REMOTE MODE F1'
Start
In promlink you should set up actual comm port, 9600 baud and 8 bit. Your programmer should be series 22. I normally use intel hex style files i.e. format 88 (series 22 does not support 386 style so files need to be 8086 style). I think the rest is pretty intuitive.
INIT.CFN is the default setting so if you save config over INIT.CFN your settings will be the default for promlink.
After a command, do not forget to press Start , otherwise the DATAIO is working in hazardous conditions!!!
the start Key should be lique "ENTER" key!!!